Idea

baxter avatar image
baxter suggested

ESS Minimum SoC 1% steps

Pls change minimum configuration steps from 5% to 1% for the ESS Minimum SoC (until grid fails).

Tia

Br

Mike

ESSSOC
2 |3000

Up to 8 attachments (including images) can be used with a maximum of 190.8 MiB each and 286.6 MiB total.

nuxland avatar image
nuxland commented

I'm also needing this, because my battery is 1860Ah 48V and 5% is like 4,5kwh. That's like 6h with my load of ~700W.
I would like to set my SOC to 13% instead of 15%.

2 |3000

Up to 8 attachments (including images) can be used with a maximum of 190.8 MiB each and 286.6 MiB total.

djbower1 avatar image
djbower1 commented

Im pretty sure your can set any percentage using mqtt

EDIT: Just tried it, and your can!

W/yourdevice/settings/0/Settings/CGwacs/BatteryLife/MinimumSocLimit

JSON

{"value": 13}

2 |3000

Up to 8 attachments (including images) can be used with a maximum of 190.8 MiB each and 286.6 MiB total.

hominidae avatar image
hominidae commented

Yes, you can but it is not even displayed correctly in the GX...I am also using 13% SoC, which technically works, but is displayed as 15% in the GX Settings-Menu

2 |3000

Up to 8 attachments (including images) can be used with a maximum of 190.8 MiB each and 286.6 MiB total.